| Specifications |
| DRAM |
- Default: 256 MB
- Maximum: 768 MB
|
| Compact Flash |
- Default: 64 MB
- Maximum: 256 MB
|
| Fixed USB 1.1 Ports |
2 |
| Onboard LAN Ports |
2-10/100 |
| Onboard AIM (Internal) Slot |
2 |
| Interface Card Slots |
4 slots, each slot can support HWIC, WIC, VIC, or VWIC type modules |
| Network-Module Slot |
1 slot, supports NM and NME type modules |
| Extension Voice Module Slot |
0 |
| PVDM (DSP) Slots on Motherboard |
2 |
| Integrated Hardware-Based Encryption |
Yes |
| VPN Hardware Acceleration (on Motherboard) |
DES, 3DES, AES 128, AES 192, and AES 256 |
| Optional Integrated In-Line Power (PoE) |
Yes, requires AC-IP power supply |
| Console Port (up to 115.2 kbps) |
1 |
| Auxiliary Port (up to 115.2 kbps) |
1 |
| Minimum Cisco IOS Software Release |
12.3(8)T |
| Rack Mountable |
Yes, 19- and 23-in. options |
| Wall Mountable |
Yes |
| Power Requirements |
| AC Input Voltage |
100 to 240 VAC, autoranging |
| AC Input Frequency |
47-63 Hz |
| AC Input Current |
2A (110V) 1A (230V) |
| AC Input Surge Current |
50A maximum, one cycle |
| AC-IP Maximum In-Line Power Distribution |
160W |
| AC-IP Input Current |
4A (110V) 2A (230V) |
| AC-IP Input Surge Current |
50A maximum, one cycle |
| DC Input Voltage |
24 to 60 VDC, autoranging positive or negative |
| DC Input Current |
- 8A (24V)
- 3A (60V)
- Startup current 50A<10 ms
|
| Typical Power Dissipation (No Modules) |
32W (109 BTU/hr) |
| Power Dissipation-AC without IP Phone Support |
170W (580 BTU/hr) |
| Power Dissipation-AC with IP Phone Support-System Only |
210W (717 BTU/hr) |
| Power Dissipation-AC with IP Phone Support-IP Phones |
160W (546 BTU/hr) |
| Power Dissipation-DC |
180W (614 BTU/hr) |
| RPS |
External only, connector for RPS provided by default |
| Recommended RPS Unit |
Cisco RPS-2300 Redundant Power System |
| Environmental Specifications |
| Operating Temperature |
32° to 104°F (0° to 40°C) |
| Non-Operating Temperature |
-40° to 158°F (-40° to 70°C) |
| Maximum Operating Temperature at Altitude |
- 40°C @ sea level
- 40°C @ 6,000 ft (1800 m)
- 30°C @ 13,000 ft (4000 m)
- 27.2°C @ 15,000 ft (4600 m)
Note: Derate 1.4°C per 1,000 ft above 6,000 ft
|
| Operating Humidity |
5 to 85%RH, non-condensing |
| Dimensions (H x W x D) |
- 1.75 x 17.25 x 16.4 in.
- (44.5 x 438.2 x 416.6 mm)
|
| Rack Height |
1 rack unit (1RU) |
| Weight (Fully Configured) |
14 lb (6.4 kg) |
| Noise Level (Min/Max) |
- 47 dBA for normal operating temperature (<90°F/32.2°C)
- 57 dBA (@ maximum fan speed)
|
There are no reviews yet.