S5735S-L24T4X-A1 Specification
|
| Typical power consumption [W] |
32.7 W |
| Typical heat dissipation [BTU/hour] |
111.58 BTU/hour |
| Maximum power consumption [W] |
47.6 W |
| Maximum heat dissipation [BTU/hour] |
162.42 BTU/hour |
| MTBF [year] |
64.3 year |
| MTTR [hour] |
2 hour |
| Availability |
>0.99999 |
| Noise at normal temperature (acoustic power) [dB(A)] |
39 dB(A) |
| Noise at normal temperature (acoustic pressure) [dB(A)] |
27.2 dB(A) |
| Number of card slots |
0 |
| Number of power slots |
0 |
| Number of fans modules |
1 |
| Redundant power supply |
Not supported |
| Long-term operating temperature [°C(°F)] |
-5°C to +50°C (23°F to 122°F) (0 m to 1800 m altitude, non-industrial optical modules)
-5°C to +55°C (23°F to 131°F) (0 m to 1800 m altitude, industrial optical modules with transmission distances less than or equal to 10 km) |
| Short-term operating temperature [°C(°F)] |
Not supported |
| Restriction on the operating temperature variation rate [°C(°F)] |
When the altitude is 1800-5000 m (5906-16404 ft.), the highest operating temperature reduces by 1°C (1.8°F) every time the altitude increases by 220 m (722 ft.).
The switch cannot be started when the ambient temperature is lower than 0°C (32°F).
The operating temperature ranges from -5°C to +45°C (23°F to 113°F) when optical modules with transmission distances greater than or equal to 70 km are used. |
| Storage temperature [°C(°F)] |
-40°C to +70°C (-40°F to +158°F) |
| Long-term operating relative humidity [RH] |
5% to 95%, noncondensing |
| Long-term operating altitude [m(ft.)] |
0-5000 m (0-16404 ft.) |
| Storage altitude [m(ft.)] |
0-5000 m (0-16404 ft.) |
| Power supply mode |
AC built-in |
| Rated input voltage [V] |
AC input: 100 V AC to 240 V AC, 50/60 Hz |
| Input voltage range [V] |
AC input: 90 V AC to 290 V AC, 45 Hz to 65 Hz |
| Maximum input current [A] |
2 A |
| Memory |
512 MB |
| Flash memory |
512 MB |
| Console port |
RJ45 |
| Eth Management port |
Not supported |
| USB |
Not supported |
| RTC |
Not supported |
| RPS input |
Not supported |
| Service port surge protection [kV] |
Common mode: ±7 kV |
| Power supply surge protection [kV] |
±6 kV in differential mode, ±6 kV in common mode |
| Types of fans |
Built-in |
| Heat dissipation mode |
Heat dissipation with fan, intelligent fan speed adjustment |
| Airflow direction |
Air intake from left and front, air exhaustion from right |
| PoE |
Not supported |
| Certification |
EMC certification
Safety certification
Manufacturing certification |
There are no reviews yet.