APC Smart-UPS VT 10kVA 208V with 1 Battery Module Expandable to 2, Start-Up 5X8, Internal Maintenance Bypass, Parallel Capable
APC Smart-UPS VT, 8000 Watts /Ā 10 kVA, Input 208V 3 PHASE / Output 120V, 208V, 208V 3PH , Interface Port DB-9 RS-232, SmartSlot , Extended runtime model
Compact three phase power protection with excellent efficiency and hot scalable runtime for small data centers and other business critical applications
Smart-UPS VT offers centralized three-phase power protection with the reliability of the award winning Smart-UPS family. Ideal for small data centers, large retail stores, regional offices, and dense power requirements, the Smart-UPS VT includes dual-mains input, automatic and maintenance bypasses, and scalable runtime with Hot-swappable batteries for increased availability. The rack mounted version maximizes valuable floor space by incorporating UPS, power distribution, and additional battery capacity in a single rack. Low cost of ownership is achieved through best-in-class efficiency and a reduction in rating of electrical infrastructure – wires, transformers, and generators due the Smart-UPS VT’s Soft Start feature. The APC Network Management Card with temperature monitoring provides remote monitoring and management through a simple Web/SNMP interface and provides integration with InfraStruXureĀ® Manager. Serviceability is greatly enhanced by user-replaceable batteries, manageable extended run frames and included start-up and standard onsite warranty services. All these features make the Smart-UPS VT the easiest UPS in its class to deploy, manage and maintain.
SUVTP10KF1B2S Features | |
Parallel-capacity capable | Increases total power capacity by using multiple UPSs simultaneously. |
Parallel-redundant capable | Power the connected equipment with multiple UPSs to increase system redundancy. |
Availability | |
Dual mains input | Increases availability by allowing the UPS to be connected to two separate power sources. |
Scalable runtime | Allows additional run time to be quickly added as needed. |
Hot-swappable batteries | Ensures clean, uninterrupted power to protected equipment while batteries are being replaced. |
Generator compatible | Ensures clean, uninterrupted power to protected equipment when generator power is used. |
Automatic internal bypass | Supplies utility power to the connected loads in the event of a UPS overload condition or fault. |
Battery modules connected in parallel | Delivers higher availability through redundant batteries. |
Serviceability | |
Battery replacement without tools | Allows quick, easy battery replacement. |
Automatic self-test | Periodic battery self-test ensures early detection of a battery that needs to be replaced. |
Shippable with modules installed | Enables pre-installation UPS staging and testing and faster installation. |
Modular design | Provides fast serviceability and reduced maintenance requirements via self-diagnosing, field-replaceable modules. |
Manageability | |
Network manageable | Provides remote management of the UPS over the network. |
InfraStruXure Manager Compatible | Enables centralized management via the APC InfraStruXure Manager. |
LCD display | Alpha-Numeric Display which displays system parameters and alarms. |
Audible alarms | Provides notification of changing utility power and UPS conditions. |
Programmable frequency | Ensures compatibility with different input frequencies. |
LED status indicators | Quickly understand unit and power status with visual indicators. |
SmartSlot | Customize UPS capabilities with management cards. |
Total Cost of Ownership | |
Input power factor correction | Minimizes installation costs by enabling the use of smaller generators and cabling. |
Temperature-compensated battery charging | Prolongs battery life by regulating the charge voltage according to battery temperature. |
Manual maintenance bypass | Reduces installation costs by eliminating the need for an external mechanical bypass. |
Intelligent battery management | Maximizes battery performance, life, and reliability through intelligent, precision charging. |
Safety | |
Frequency and voltage regulation | Gives higher application availability by correcting poor frequency and voltage conditions without using the battery. |
Safety-agency approved | Ensures the product has been tested and approved to work safely with the connected service provider equipment and within the specified environment. |
Cold-start capable | Provides temporary battery power when the utility power is out. |