Eaton Tripp Lite Series 18.7kW 3-Phase Monitored PDU w/LX Platform, 208/240V Output (36 C13), IEC 309 60A Blue, 0U, TAA


Quick tech specs

  • Phase Monitored PDU w/LX Platform, 208/240V Output (36 C13), IEC 309 60A Blue, 0U, TAA
  • 26 A
  • 18.7 kW
  • Ethernet 10/100
  • output connectors: 36 (36 x IEC 60320 C13)
  • 6 ft cord
  • Power distribution unit (rack-mountable)
  • AC 208/240 V
  • 3-phase
  • input: IEC 60309 60A
  • 0U
  • TAA Compliant

AED20,399.00

Know your gear

3-Phase PDU Distributes and Monitors Network-Grade Power
Recommended for data centers, server rooms and network closets, the 18.7kW PDU3EVN6G60C provides real-time remote monitoring of voltage and load levels via built-in network connection. A six-foot (1.8-meter) cord with IEC 309 60A Blue (3P+E) input plug connects the 3-phase PDU to a compatible AC power source, generator or protected UPS. The firmware can be easily upgraded to ensure the 0U PDU continues to perform at its best as connected equipment adds new features.
36 Outlets Dispense AC Power
During normal operation, 36 C13 outlets distribute AC power to connected equipment. Each 208/240V outlet is accompanied by an LED that illuminates when the outlet is ramped up and ready to be used. The outlets are split into six load banks, each protected by a 20A circuit breaker that trips if the bank’s connected load exceeds its maximum load rating. Plug-lock insert sleeves are included to prevent connected cables from becoming accidentally dislodged.
Ā LX Platform Network Management Card Allows Remote Access 24/7
The Java-free HTML5-based LX Platform network interface enables full remote access for PDU status monitoring and email notifications via secure web browser, SNMP, telnet or SSH. It supports 10/100 Mbps auto-sensing for optimum communication with an Ethernet network. Optional EnviroSense2 modules (sold separately) provide a variety of environmental monitoring capabilities. Protocols supported include IPv4, IPv6, HTTP, HTTPS, SMTP, SNMPv1, SNMPv2, SNMPv3, telnet, SSH, FTP, DHCP and NTP. The 0U PDU can receive IP address assignments via DHCP server (automatic) or static (manual) method.
Color Touchscreen LCD Offers Important Data at a Glance
An easy-to-navigate color touchscreen LCD reports network data, including IP address, input current level per phase, and output current per load bank with ±1% billing-grade accuracy. It also generates a unique QR code to allow read-only access to the 3-phase PDU via mobile device. If an EnviroSense2 module is connected to the PDU, the LCD also displays its status and environmental data, such as temperature and humidity.
Easy to Install Vertically in an EIA-Standard 19 in. Rack
The 0U PDU mounts vertically using the included toolless mounting buttons or the included rack-mounting brackets. Spare buttons are also included. Use the included PDUMVROTATEBRKT kit to install the 3-phase PDU with outlets facing the rear for better airflow or equipment access.
TAA-Compliant for GSA Schedule Purchases
The PDU3EVN6G60C is compliant with the Federal Trade Agreements Act (TAA), which makes it eligible for GSA (General Services Administration) Schedule and other federal procurement contracts.
SKU: PDU3EVN6G60C Category: Tag:
Category Attribute Value
Overview Brand Tripp Lite
Product Line Eaton Tripp Lite Series
Model 18.7kW 3-Phase Monitored PDU w/LX Platform, 208/240V Output (36 C13), IEC 309 60A Blue, 0U, TAA
Manufacturer Tripp Lite
Network & Communication Remote Management HTTP, HTTPS, NTP, SMTP, SNMP 1, SNMP 2, SNMP 3, SSH, Telnet
Remote Management Interface Ethernet 10/100
Connectivity Input Connectors 1
Interface Provided 1 x management – RJ-45, 1 x management (Fast Ethernet) – RJ-45, 1 x USB – 4 pin USB Type B, 2 x USB – 4 pin USB Type A
Power Emergency Power Off Built-in LX platform interface, Current meter, Digital power meter, Email alerts support, LED indicators, Monitored, Overload protection, Touch screen LCD display, Voltage monitoring
Frequency Provided 50/60 hertz
Input Connector Type Power IEC 60309 60A
Input Wiring 3-phase
Max Input Current 26 ampere
Output Connector Quantity 36
Output Connector Type 36 x power IEC 60320 C13
Power Output Connectors Details 36 x power IEC 60320 C13 – 240 V 12 A
Power Provided 18.7 kilograms per millimetere (assumed to mean kVA or watt, possibly 18.7 kVA)
Provided Voltage AC 208/240 volt
Required Voltage AC 208/240 volt
Technical Information Form Factor (Power Device) Rack-mountable
Max Operating Temperature 122 degree Fahrenheit
Min Operating Temperature 32 degree Fahrenheit
Operating Humidity 5 – 95% (non-condensing)
Protection Type Circuit breaker
Product Information Cord Length 6 ft
Features Vertical orientation
Packaged Quantity 1
Product Type Power distribution unit
Rack Mounting Kit Included
Subcategory Power distribution devices
Included Items Cables Management cable – external, Power cable – integrated – 6 ft
Included Accessories 36 plug-lock insert sleeves
Dimensions & Weight Height 70 inch
Height (Rack Units) 0
Weight 18.65 lbs
Width 2.2 inch
Depth 2.5 inch
Physical Characteristics Color Category Black

Based on 0 reviews

0.0 overall
0
0
0
0
0

Be the first to review “Eaton Tripp Lite Series 18.7kW 3-Phase Monitored PDU w/LX Platform, 208/240V Output (36 C13), IEC 309 60A Blue, 0U, TAA”

There are no reviews yet.