Tripp Lite OMNI1000ISO 1000VA Line-Interactive UPS Tower Battery Backup


Interface Types:Ā IEC 5-15P

Bays/Ports/Slots:Ā 7

U Height:Ā 2U

Wattage/VA:Ā 700W

Voltage:Ā 110-120V

2,399.00 د.إ

Tripp Lite OmniSmart OMNI1000ISO 120V 1000VA 700W Line-Interactive UPS Tower Battery Backup w/ Built-In Isolation Transformer, USB port – Brand New

Tripp Lite OmniSmart OMNI1000ISO 120V / 120 Volt 1000VA / 1000 Volt-Amps 700W / 700 Watts Line-Interactive UPS / Uninterruptible Tower Battery Backup 6 UPS-supported AC outlets with Built-in Isolation Transformer with Faraday shield & USB / Universal Serial Bus communications port – Brand New

OmniSmart 120V 1000VA 700W Line-Interactive UPS, Tower, Built-In Isolation Transformer, USB port

Description
Tripp Lite’s OMNI1000ISO offers complete UPS protection with built-in line-interactive voltage regulation, intelligent monitoring and unattended shutdown capability. Built-in isolation transformer with Faraday shield offers full isolation and complete common mode noise rejection. 1000VA power-handling capacity supports point-of-sale applications, computers, internetworking equipment and home theater systems during commercial power failures. Line-interactive voltage regulation corrects brownouts as low as 81V and overvoltages as high as 143V back to normal 120V levels, reserving battery power for use during complete power failures. USB communications port works with PowerAlert Software and cabling to provide automatic unattended shutdown of connected network and PC applications.

Features

  • 1000VA line-interactive UPS with Faraday-shielded, low-impedance isolation transformer delivers full isolation from potential damage and performance problems
  • Provides immunity from EMI/RFI line noise in both normal and common modes. Delivers clean signal reference ground, reducing data errors and audio/video distortion
  • Automatic voltage regulation (AVR) automatically corrects incoming voltage to keep equipment working through low voltage (brownouts) as low as 81V and overvoltages as high as 143V without consuming battery power Supports loads up to 1000VA/700W
  • Half-load runtime of 24 min. (500VA/350W); full load runtime of 8 min. (1000VA/700W)
  • 5 diagnostic LEDs indicate AC present, on battery, voltage correction status, overload and battery low/replace
  • Electrostatic discharge (ESD) resistance reduces potential static damage to connected electronics
  • USB port enables data-saving unattended shutdown when used with Tripp Lite’s PowerAlert software, available via FREE download fromĀ Tripp Lite PowerAlert Platform
  • Built-in surge suppression (backed by $200,000 Ultimate Lifetime Insurance U.S., Canada, and Puerto Rico only) safeguards connected equipment against damage
  • SURGE VOLTAGE WITHSTAND CAPABILITY: ANSI/IEEE C62.41 Catagories A & B 6KV/200/500 amp 100Khz Ringwave and category B BiWave
  • SURGE VOLTAGE ATTENUATION: N-G 2000:1, L-G 240:1, L-N 100:1
  • INSERTION LOSS: 65 db N-G from 10Khz to 100Khz, 45 to 60 db L-G from 10Khz to 100Khz, 18 to 54 db L-N from 50Khz to 500 Khz
  • 6 UPS-supported AC outlets; 6-ft. cord
  • Optional PDUB15 bypass PDU enables hot-swappable UPS replacement with no disruption to connected equipment

 

Highlights

Overview

  • 1000VA / 1kVA tower 120V line interactive UPS with isolation transformer
  • Corrects brownouts and overvoltages from 81V to 143V
  • USB port, Normal & common mode EMI/RFI line noise immunity
  • NEMA 5-15P input plug and 6 5-15R outlets

 

Package Includes

  • OMNI1000ISO UPS System
  • USB cable
  • Instruction manual
SKU: OMNI1000ISO Category:
TRIPP LITE LINE-INTERACTIVE UPS BATTERY BACKUP
Model Number OMNI1000ISO
OVERVIEW
UPS Type Line-Interactive
OUTPUT
Output Volt Amp Capacity (VA) 1000
Output kVA Capacity (kVA) 1
Output Watt Capacity (Watts) 700
Power Factor

The ratio of active power (watts) to apparent power (VA). Most computer-related equipment has a power factor between 0.6 and 0.8. Power factor is the spread between VA and wattage. For example, VA x power factor = watts

0.7
Nominal Voltage Details 115v nominal output in battery mode
Frequency Compatibility 60 Hz
Output Voltage Regulation (Line Mode)
  • -18%
  • +8%
Output Voltage Regulation (Battery Mode) +/- 5%
Hot-Swap PDU options PDUB15 (2U / 8 5-15R outlets)
Output AC Waveform (AC Mode) Sine wave
Output AC Waveform (Battery Mode) PWM sine wave
Nominal Output Voltage(s) Supported
  • 110V
  • 115V
  • 120V
Output Receptacles (6) 5-15R
Individually Controllable Load Banks

Select UPS models have their receptacles divided into one or more load banks (labeled LOAD 1, ect.) which may be remotely switched OFF and ON using Tripp Lite UPS software without interrupting power to equipment connected to the other outlets

No
INPUT
Rated input current (Maximum Load) 7.6A
Nominal Input Voltage(s) Supported 120V AC
UPS Input Connection Type 5-15P
Input Circuit Breakers 15A
UPS Input Cord Length (ft.) 6
Recommended Electrical Service 15A 120V
Input Phase Single-Phase
BATTERY
Full Load Runtime (min.)

The amount of runtime th UPS will offer when you

8 min. (700w)
Half Load Runtime (min.)

The amount of runtime th UPS will offer when you

24 min. (350w)
DC System Voltage (VDC) 36
Battery Recharge Rate (Included Batteries) Less than 4.5 hours from 10% to 90%
Internal UPS Replacement Battery Cartridge Qty 2Ā RBC53
Battery Access Battery Access Door
Battery Replacement Description
  • Hot-swappable
  • User replaceable batteries
Expandable Runtime No
VOLTAGE REGULATION
Voltage Regulation Description Automatic voltage regulation (AVR) maintains line power operation with an input voltage range of 85 to 143
Overvoltage Correction

A feature found in line conditioners and select UPS systems that maintains mains-level power to equipment when prolonged line voltages are lower than normal

Input voltages between 128 and 143V are reduced by 9%
Undervoltage Correction

A feature found in line conditioners and select UPS systems that maintains mains-level power to equipment when prolonged line voltages are lower than normal

Input voltages between 96 and 107V are boosted by 10%
Severe Undervoltage Correction Input voltages between 85 and 95V are boosted by 20%
USER INTERFACE, ALERTS & CONTROLS
Switches 2 Switches control off/on power status and alarm-cancel/self-test operation
Alarm Cancel Operation
  • Power-fail alarm can be silenced using alarm-cancel switch
  • Once silenced, alarm will re-sound to indicate low-battery status
Audible Alarm Audible alarm indicates power-failure and low-battery conditions
LED Indicators 5 LEDs indicate:

  • Line power
  • Battery power
  • Overload
  • Voltage Regulation
  • Battery Low/Replace Status
SURGE / NOISE SUPPRESSION
UPS AC Suppression Joule Rating 510
EMI / RFI AC Noise Suppression

Technology found in select UPS systems that protects against EMI (electromagnetic interference) and RFI (radio frequency interference) line noise and protects equipment against associated incremental hardware damage, data corruption and audio/video transmission problems.

Yes
ISOLATION
Output Isolation Transformer

A feature found in isolation transformers and select UPS systems where the output power is fully isolated from EMI/RFI line noise, protecting sensitive equipment from potential damage and performance problems

Professional grade load isolation transformer
Surge Voltage Withstand Capability ANSI/IEEE C62.41 Categories A & B 6KV/200/500 amp 100Khz Ringwave and category B BiWave
Surge Voltage Attenuation
  • N-G 2000:1
  • L-G 240:1
  • L-N 100:1
Insertion Loss

The los of signal power resulting from the insertion of a device in a transmission line or optical fiber. Is usually expressed in decibels (dB)

  • 65 db N-G from 10Khz to 100Khz
  • 45 to 60 db L-G from 10Khz to 100Khz
  • 18 to 54 db L-N from 50Khz to 500 Khz
PHYSICAL
Cooling Method Fan
Installation Form Factors Supported with Included Accessories Tower
Installation Form Factors Supported with Optional Accessories Wallmount (UPSWM – tower mounting kit)
Primary Form Factor Tower
Primary UPS Depth (mm) 234
Primary UPS Height (mm) 325
Primary UPS Width (mm) 191
Shipping Dimensions (hwd / in.) 16.90 x 13.50 x 11.30
Shipping Weight (lbs.) 46.10
UPS Housing Material PVC
UPS Power Module Dimensions (hwd, in.) 12.8 x 7.5 x 9.2
UPS Power Module Weight (kg) 16.51
UPS Power Module Weight (lbs.) 36.4
ENVIRONMENTAL
Operating Temperature Range +32 to +104 degrees Fahrenheit / 0 to +40 degrees Celsius.
Storage Temperature Range +5 to +122 degrees Fahrenheit / -15 to +50 degrees Celsius.
Relative Humidity Up to 95%, non-condensing
AC Mode Efficiency Rating (100% Load) >91%
COMMUNICATIONS
Communications Interface USB
PowerAlert Software For local monitoring via the UPS’s built-in USB communications port, download PowerAlert Local software atĀ http://www.tripplite.com/poweralert
Communications Cable USB interface cable included
WatchDog Compatibility Supports Watchdog application, OS and hard-reboot restart options for remote applications
LINE / BATTERY TRANSFER
Transfer Time

The time it takes for a UPS to switch from AC on-line mode to DC battery-powered mode. Measured in milliseconds (ms)

2-4 milliseconds
Low Voltage Transfer to Battery Power (Setpoint) 81
High Voltage Transfer to Battery Power (Setpoint) 143
SPECIAL FEATURES
Cold Start (Startup in Battery Mode During a Power Failure) Cold-start operation supported
High Availability UPS Features Hot Swappable Batteries
CERTIFICATIONS
UPS Certifications
  • Tested to UL1778 (USA)
  • Tested to CSA (Canada)
  • Tested to NOM (Mexico)
  • Meets FCC Part 15 Category A (EMI)
WARRANTY
Product Warranty Period (U.S. & Canada) 2-year limited warranty
Connected Equipment Insurance (U.S., Canada & Puerto Rico) $200,000Ā Ultimate Lifetime Insurance

Based on 0 reviews

0.0 overall
0
0
0
0
0

Be the first to review “Tripp Lite OMNI1000ISO 1000VA Line-Interactive UPS Tower Battery Backup”