Power distribution unit
Raritan Smart Primary PRO1 Configurable Alt Phase Hdot Outlets, 415V 3PH Wye 12BR 60A
Power distribution unitRaritan Smart Primary PRO1 Configurable Alt Phase Hdot Outlets, 415V 3PH Wye 12BR 60A
- HDOT Cx Outlets: Cx is the future-ready UL tested hybrid of a C13 and C19 outlet accommodating both C14 and C20 plugs.
- Network Monitoring: Gain access to valuable data through connections including HTTP(S), SSH, Telnet, SNMP, (S)FTP, SMTP, Syslog, LDAP(S), RS-232 serial, and more.
- Hot-Swap Network Card: Network access is ensured when power is lost to the Primary unit with backup power provided by the Linked unit.
- Star Multi-Linking: PRO2 provides the ability to link up to four power circuits using one IP address. Primary Expansion PDU provides backup power to network card.
- Temperature/Humidity Monitoring: Primary and Expansion (select products) units each support two external 10′ (3m) T/H probes. Receive SNMP-based alerts and email notifications.
- IP Access, Security & Communications: Web, SSH, Telnet, SNMPv2c & v3, RS-232 serial, 10/100 Base T-Ethernet, LDAP(S), TACACS+, RADIUS, DHCP, & SMTP/email.
- Auto-Flip Current Display: Easy-to-read LEDs display current per phase to help prevent overloads and simplify three-phase load balancing in high-density cabinets.
- Per-Inlet Power Sensing: PIPSĀ® (Per Inlet Power Sensing) Monitors Current Load (A), Voltage (V), Power (W), Apparent Power (VA), Crest Factor, Power Factor, & Energy per inlet.
- Branch Circuit Protection: This PDU meets the UL and IEC 62368-1 requirement for branch circuit protection through UL 489 rated magnetic-hydraulic circuit breakers or UL 248 fuses.
- HDOT (High Density Outlet Technology): The highest outlet density available in a network connected PDU. Meets IEC C13 and C19 specifications, plus high native retention, and UL94V-0 flame rating.
- High Temperature Rating: This product has been tested and approved for safe and reliable operation in 60 °C data center environments.
- Flexible Mounting: Includes standard button mounts along with provisions for custom mounting brackets.
- Color-Coded Options: Select from six colors to designate PDU circuits in the data center-black, white, red, green, blue, and yellow.
SKU: C1S24TB-5QAE2766 -
-
-
Power distribution unit
Raritan Switched Pops PRO3X with Pips, 0U, 36 Ramlock Hdot Outlets (18 C13 + 18 CX), Color
Power distribution unitRaritan Switched Pops PRO3X with Pips, 0U, 36 Ramlock Hdot Outlets (18 C13 + 18 CX), Color
- HDOT Cx Outlets
- Cx is the future-ready UL tested hybrid of a C13 and C19 outlet accommodating both C14 and C20 plugs.
- Network Monitoring
- Gain access to valuable data through connections including HTTP(S), SSH, Telnet, SNMP, (S)FTP, SMTP, Syslog, LDAP(S), RS-232 serial, and more.
- Multi-Unit Linking & Cascading
- Daisy chain up to 16 PDUs from a primary PDU using a USB or Ethernet connection through a single IP address.
- Multi-Color LCD
- An easy-to-read LCD provides a local indication of power usage, alerts, and alarms.
- Hot Swappable Controller
- The Controller is the PDU’s center of intelligence and houses computing, display, and connectivity ports.
- RamLock Locking Outlets
- A mechanical locking mechanism built to secure the broadest range of C14 and C20 plugs in place.
- Environmental Monitoring
- Support up to 12 daisy chained DX2-series SmartSensors, each with the ability to send SNMP-based alerts and email notifications.
- Per-Inlet Power Sensing
- PIPSĀ® (Per Inlet Power Sensing) Monitors Current Load (A), Voltage (V), Power (W), Apparent Power (VA), Crest Factor, Power Factor, & Energy per inlet.
- Per-Outlet Power Sensing
- POPSĀ® (Per Outlet Power Sensing) Monitors Current Load (A), Voltage (V), Power (W), Apparent Power (VA), Crest Factor, Power Factor, and Energy per outlet.
- Branch Current Monitoring
- Monitors current at each breaker branch and provides SNMP-based alerts and emails on high usage that risks a tripped circuit.
- Branch Circuit Protection
- This PDU meets the UL and IEC 62368-1 requirement for branch circuit protection through UL 489 rated magnetic-hydraulic circuit breakers or UL 248 fuses.
- Outlet Control
- On Switched PDUs, cycle power to individual outlets or groups of outlets to reboot servers, or power off unused receptacles.
- High Temperature Rating
- This product has been tested and approved for safe and reliable operation in 60 °C data center environments.
- Flexible Mounting
- Includes standard button mounts along with provisions for custom mounting brackets.
- Color – Coded Options
- Select from six colors to designate PDU circuits in the data center – black, white, red, green, blue, and yellow.
SKU: C3WG36RLDQJE2MT2C -
Power distribution unit
Raritan Switched. 208V Delta 60A IEC 60309 3P+G 9HR
- Industrial-grade durability – Handles 60A loads for high-demand environments
- Phase balancing support – Maintains stable 3-phase delta power
- Remote outlet control – Individual port switching via web interface
SKU: PX4-232A-E7V2