Power distribution unit
Server Technology Smart MST 48ALT Phase Outlt Hdot 208V 3PH Delta 6BR 50A CS8365
Power distribution unitServer Technology Smart MST 48ALT Phase Outlt Hdot 208V 3PH Delta 6BR 50A CS8365
- Network Monitoring
- Temperature/ Humidity Monitoring
- Branch Current Monitoring
- High-Density Outlet Technology
- Flexible Mounting
- Hot-Swap Network Card
- Auto-Flip Current Display
- Branch Circuit Protection
- High Retention Locking Outlets
- Color Identification
SKU: C2S48TE-DFME2M99 -
Power distribution unit
Server Technology Smart Pops Expansion PRO2 (48) Configurable Alt Phase Hdot Outlets, 208V 3PH
Power distribution unitServer Technology Smart Pops Expansion PRO2 (48) Configurable Alt Phase Hdot Outlets, 208V 3PH
- HDOT Cx Outlets:
- Cx is the future-ready UL tested hybrid of a C13 and C19 outlet accommodating both C14 and C20 plugs.
- Network Monitoring:
- Gain access to valuable data through connections including HTTP(S), SSH, Telnet, SNMP, (S)FTP, SMTP, Syslog, LDAP(S), RS-232 serial, and more.
- Hot-Swap Network Card:
- Network access is ensured when power is lost to the Primary unit with backup power provided by the Linked unit.
- Star Multi-Linking
- : PRO2 provides the ability to link up to four power circuits using one IP address. Primary Expansion PDU provides backup power to network card.
- Temperature/Humidity Monitoring:
- Primary and Expansion (select products) units each support two external 10′ (3m) T/H probes. Receive SNMP-based alerts and email notifications.
- IP Access , Security & Communications
- : Web, SSH, Telnet, SNMPv2c & v3, RS-232 serial, 10/100 Base T-Ethernet, LDAP(S), TACACS+, RADIUS, DHCP, & SMTP/email.
- Auto-Flip Current Display:
- Easy-to-read LEDs display current per phase to help prevent overloads and simplify three-phase load balancing in highdensity cabinets.
- Per-Inlet Power Sensing:
- PIPSĀ® (Per Inlet Power Sensing) Monitors Current Load (A), Voltage (V), Power (W), Apparent Power (VA), Crest Factor, Power Factor, & Energy per inlet.
- Per-Outlet Power Sensing
- : POPSĀ® (Per Outlet Power Sensing) Monitors Current Load (A), Voltage (V), Power (W), Apparent Power (VA), Crest Factor, Power Factor, and Energy per outlet.
- Branch Current Monitoring
- : Monitors current at each breaker branch and provides SNMPbased alerts and emails on high usage that risks a tripped circuit.
- Branch Circuit Protection
- : This PDU meets the UL and IEC 62368-1 requirement for branch circuit protection through UL 489 rated magnetichydraulic circuit breakers or UL 248 fuses.
- Alternating-Phase Outlets:
- Evenly distributes multiple phases of power to each outlet for simplified load balancing, reduced cord lengths, and better airflow.
- High Temperature Rating:
- This product has been tested and approved for safe and reliable operation in 60 °C data center environments.
- Flexible Mounting:
- Includes standard button mounts along with provisions for custom mounting brackets.
- Color-Coded Options
- : Select from six colors to designate PDU circuits in the data center – black, white, red, green, blue, and yellow.
SKU: C2SG48TE-DQME2M99 -
Power distribution unit
Server Technology Switch MST 42ALT Phase Outlt Hdot 208V 3PH Delta 6BR 50A CS8365
Power distribution unitServer Technology Switch MST 42ALT Phase Outlt Hdot 208V 3PH Delta 6BR 50A CS8365
- Network Monitoring
- Temperature/ Humidity Monitoring
- Branch Current Monitoring
- High-Density Outlet Technology
- Flexible Mounting
- Hot-Swap Network Card
- Auto-Flip Current Display
- Branch Circuit Protection
- High Retention Locking Outlets
- Color Identification
SKU: C2W42CE-DFME2M00 -
-
Power distribution unit
Server Technology Switched Master PRO2 (36) Configurable Alt Phase Hdot Outlets, 208V 3PH Wye
Power distribution unitServer Technology Switched Master PRO2 (36) Configurable Alt Phase Hdot Outlets, 208V 3PH Wye
- HDOT Cx: Cx is the future ready UL tested hybrid of the C13 and C19 outlets accommodating both C20 and C14 plugs.
- Network Monitoring: Gain access to valuable data through connections including HTTP(S), SSH, Telnet, SNMP, (S)FTP, SMTP, Syslog, LDAP(S), RS-232 serial, and more.
- Hot-Swap Network Card: Network access is ensured when power is lost to the primary unit with backup power provided by the primary link unit.
- Star Multi-Linking: Provides the ability to link up to four power circuits using one IP address. Primary link provides backup power to network card.
- Temperature/Humidity Monitoring: Primary and Link units each support two external 10′ (3m) T/H probes. Receive SNMP-based alerts and email notifications.
- Auto-Flip Current Display: Easy-to-read LEDs display current per phase to help prevent overloads and simplify three-phase load balancing in high-density cabinets.
- Per- Inlet Power Sensing: Meets ANSI C12.1 for billing-grade accuracy of Current per phase. PIPS includes voltage, active power, apparent power, power factor, and energy.
- Branch Current Monitoring: Monitors current at each breaker branch and provides SNMP-based alerts and emails on high usage that risks a tripped circuit.
- Branch Circuit Protection: This PDU meets the UL and IEC 60950-1 requirement for branch circuit protection through use of UL489 rated magnetic-hydraulic circuit breakers or UL248 fuses.
- Outlet Control: On Switched rack PDUs, cycle power to individual outlets or groups of outlets to reboot servers. Or, power off unused receptacles.
- Alternating-Phase Outlets: Evenly distributes multiple phases of power to each outlet for simplified load balancing, reduced cord lengths, and better airflow.
- High Temperature Rating: This product has been tested and approved for safe and reliable operation in 60 °C data center environments.
- Flexible Mounting: Includes standard button mounts along with provisions for custom mounting brackets.
- Color Identification: Choose from six colors to designate circuits for rack PDUs in the data center. Color options include Blue, Red, Green, White, Yellow, and Black
SKU: C2W36TE-YQME2M99 -
Power distribution unit
Server Technology Switched MST 18-C13 6-C19 3PHASE Delta 30A Input with IEC 60309
Power distribution unitServer Technology Switched MST 18-C13 6-C19 3PHASE Delta 30A Input with IEC 60309
- Multi-connector support – accommodates C13 and C19 devices
- Delta configuration – efficient for 208V 3-phase environments
- Durable construction – rack-mountable industrial design
SKU: C1W24VS-DPFA13A1 -
Power distribution unit
Server Technology Switched MST 18-C13 6-Cxhdot 230V 1-Phase 32A IEC 60309
- Network Monitoring
- Temperature/ Humidity Monitoring
- Branch Current Monitoring
- High-Density Outlet Technology
- Hot-Swap Network Card
- Per-Inlet Power Sensing
- Branch Circuit Protection
- High Retention Locking Outlets
- Star Multi-Linking
- Per-Outlet Power Sensing
SKU: C2WG24SN-EPJN5D6 -
-
Power distribution unit
Server Technology Switched PRO1 with Pips (Per Input Power Sensing), 0U, 18 x IEC C13 & 6 x IEC C19
Power distribution unitServer Technology Switched PRO1 with Pips (Per Input Power Sensing), 0U, 18 x IEC C13 & 6 x IEC C19
- Network Monitoring
- Hot-Swap Network Card
- Star Multi-Linking
- Temperature/Humidity Monitoring
- Auto-Flip Current Display
- Per-Inlet Power Sensing
- Branch Circuit Protection
- Outlet Control
- High Retention Locking Outlets
- High Temperature Rating
SKU: STV-4541K -
Power distribution unit
Server Technology Switched PRO1, Per Input Power Sensing, 2U, 16 x IEC C13 Outlets, Input Amp Meter, 208V
Power distribution unitServer Technology Switched PRO1, Per Input Power Sensing, 2U, 16 x IEC C13 Outlets, Input Amp Meter, 208V
- Network Monitoring
- Temperature/ Humidity Monitoring
- Branch Circuit Protection
- High Temperature Rating
- Hot-Swap Network Card
- Auto-Flip Current Display
- Outlet Control
- Color Identification
- Star Multi-Linking
- Per-Inlet Power Sensing
SKU: C1W16HR-2CAA5BAC