APC SURT6000RMXLT3U Smart-UPS 6000VA 208V UPS Battery Backup


U Height:Ā 3U

Wattage/VA:Ā 4200W

Voltage:Ā 208V

19,999.00 د.إ

Availability

 

  • Automatic internal bypass – Supplies utility power to the connected loads in the event of a UPS power overload or fault.
  • Scalable runtime – Allows additional run time to be quickly added as needed.
  • Intelligent battery management – Maximizes battery performance, life, and reliability through intelligent, precision charging.
  • Hot-swappable batteries – Ensures clean, uninterrupted power to protected equipment while batteries are being replaced
  • Automatic restart of loads after UPS shutdown – Automatically starts up the connected equipment upon the return of utility power.
  • Temperature-compensated battery charging – Prolongs battery life by regulating the charge voltage according to battery temperature.

 

Manageability

 

  • Network manageable – Provides remote power management of the UPS over the network.
  • InfraStruXure Manager Compatible – Enables centralized management via the APC InfraStruXure Manager.
  • SmartSlot – Customize UPS capabilities with management cards.
  • LED status indicators – Quickly understand unit and power status with visual indicators.
  • Serial connectivity – Provides management of the UPS via a serial port.

 

Adaptability

 

  • Plug-and-Play external batteries – Ensures clean, uninterrupted power to the loads when adding extra runtime to the UPS.
  • Rack/Tower convertible – Protects the initial investment in the UPS when migrating from tower to rack-mount environment.
  • Flash upgradeable firmware – Install maintenance releases of firmware remotely using FTP.

 

Serviceability

 

  • User-replaceable batteries – Increases availability by allowing a trained user to perform upgrades and replacements of the batteries reducing Mean Time to Repair (MTTR)
  • Automatic self-test – Periodic battery self-test ensures early detection of a battery that needs to be replaced.
  • Predicitive failure notification – Provides early-warning fault analysis ensuring proactive component replacement.
  • Disconnected battery notification – Warns when a battery is not available to provide backup power.
  • Audible alarms – Provides notification of changing utility power and UPS power conditions

 

Protection

 

  • Frequency and voltage regulation – Gives higher application availability by correcting poor frequency and voltage conditions without using the battery.
  • Power conditioning – Protects connected loads from surges, spikes, lightning, and other power disturbances.
  • Input power factor correction – Minimizes installation costs by enabling the use of smaller generators and cabling.
  • Generator compatible – Ensures clean, uninterrupted power to protected equipment when generator power is used.
  • Cold-start capable – Provides temporary battery power when the utility power is out.
  • Resettable circuit breaker – Easy recovery from overloads; no need to replace a fuse.
  • Safety-agency approved – Ensures the product has been tested and approved to work safely with the connected service provider equipment and within the specified environment.

 

SKU: SURT6000RMXLT3U Category:
SPECIFICATIONS
Model number SURT6000RMXLT3U
OUTPUT
Output Power Capacity 4200 Watts / 6000 VA
Max Configurable Power 4200 Watts / 6000 VA
Normal Output Voltage 208V
Output Voltage Note Configurable for 208 or 240 nominal output voltage
Efficiency at Full Load 92.0%
Output Voltage Distortion Less than 3%
Output Frequency (sync to mains) 50/60 Hz +/- 3 Hz user adjustable +/- 0.1
Other Output Voltages 240
Crest Factor 3 : 1
Topology Double Conversion Online
Waveform Type Sine wave
Output Connections (2) NEMA L6-20R
(2) NEMA L6-30R
Bypass Internal Bypass (Automatic or Manual)
INPUT
Nominal Input Voltage 208V
Input Frequency 50/60 Hz +/- 5 Hz (auto sensing)
Input Connections NEMA L6-30P
Cord Length 10 feet (3.05 meters)
Input voltage range for main operations 160 – 280V
Input voltage adjustable range for mains operation 100 – 280V
Other Input Voltage 240
BATTERIES & RUNTIME
Battery Type Maintenance-free sealed Lead-Acid battery with suspended electrolyte
leakproof
Included Battery Modules 2
Typical recharge time 2.50 hour(s)
Replacement Battery APCRBC140
RBC Quantity 1
Extended Run Options 3 Hours 0 Minutes
COMMUNICATIONS & MANAGEMENT
Interface Port(s) DB-9 RS-232
RJ-45 10/100 Base-T
Smart-Slot
Pre-Intalled SmartSlot Cards AP9631
Control panel LED status display with load and battery bar-graphs and On Line
On Battery
Replace Battery
Overload and Bypass Indicators
Audible Alarm Alarm when on battery
distinctive low battery alarm
overlad continuous tone alarm
Emergency Power Off (EPO) Yes
SURGE PROTECTION AND FILTERING
Surge energy rating 555J Joules
Filtering Full time multi-pole noise filtering
0.3% IEEE surge let-through
zero clamping response time
meets UL 1449
PHYSICAL
Maximum Height (in/mm) 17.00/432
Maximum Width (in/mm) 5.10/130
Maximum Depth (in/mm) 26.00/660
Rack Height 3U
Net Weight (lb/kg) 120.00/54.55
Shipping Weight (lb/kg) 140.00/63.64
Shipping Height (in/mm) 13.68/347
Shipping Width (in/mm) 23.73/603
Shippimg Depth (in/mm) 38.60/980
Color Black
Units per Pallet 6.00
ENVIRONMENTAL
Operating Environment 32 – 104 °F (0 – 40 °C)
Operating Relative Humidity 0 – 95% no %
Operating Elevation 0-10000 feet (0-3000 meters)
Storage Temperature 5 – 113 °F (-15 – 45 °C)
Storage Relative Humidity 0 – 95% no %
Storage Elevation 0-50000 feet (0-15000 meters)
Audible noise at 1 meter from surface of unit 55.00 dBA
Online Thermal Dissipation 1324.00 BTU/hr
Protection Class IP 20
CONFORMANCE
Regulatory Approvals CSA
FCC Part 15 Class A
UL 1778
SUSTANABLE OFFER STATUS
RoHS Compliant
REACH REACH
Contains No SVHCs
Battery Directive Compliant
Battery Notes Contains Lithium Coin Cell

Based on 0 reviews

0.0 overall
0
0
0
0
0

Be the first to review “APC SURT6000RMXLT3U Smart-UPS 6000VA 208V UPS Battery Backup”