APC Symmetra RM 2kVA Scalable to 6kVA N+1 208/240V w/ 208 to 120V Step-Down Transformer (4) L5-20R


AED39,799.00

Overview

Parameter Value
Lead Time Usually in Stock
Run Time for Load 12 min 15 s at 1400 W (Min-max: 140–1400 W)
Max. Capacity Used 100%
Main Input Voltage 208 V
Product Type Uninterruptible Power Supply (UPS)
Main Output Voltage 120 V, 208 V
kW Rating 1400 W
Rated Power (VA) 2000 VA
Input Connection Type NEMA L6-30P 30 A
Output Connection Type 4 Ɨ NEMA L5-20R, 2 Ɨ NEMA L6-20R
Rack Units 10U
Cable Length 10 ft (3.05 m)
Number of Cables 1
Battery Type Lead-Acid Battery
Provided Equipment User Manual, Rack Mounting Brackets, Rack Mounting Support Rails, CD with Software
Product Range Symmetra

Batteries & Runtime

Parameter Value
Run Time View Runtime Graph
Included Battery Modules 1
Battery Slots Empty 4
Typical Recharge Time 4 h
Additional Info UPS accepts 1–4 additional battery packs
Configurable Output Voltage 220 / 230 / 240 V
Battery Charge Power 153 W rated
Battery Life 3–5 years
Extendable Run Time Yes (1)

General

Parameter Value
Product Web Sub-Family 2kVA power increments
Total Power Modules 4
Preinstalled Power Modules 1
Free Power Module Slots 0
Filled Power Module Slots 0
Redundant Yes

Physical

Parameter Value
Color Black
Height 17.52 in (44.5 cm)
Width 19.02 in (48.3 cm)
Depth 28.74 in (73 cm)
Net Weight 259.55 lb (117.73 kg)
Mounting Location Front
Mounting Preference Lower
Mounting Mode Rack-mounted
Two Post Mountable No (0)
USB Compatible No

Input

Parameter Value
Input Frequency 50/60 Hz ± 5 Hz (auto-sensing)
Input Connectors 1 Hard Wire (3-wire: 2PH + G)
Voltage Range (Efficiency) 155–276 V
Input Power Factor (Full Load) 0.98

Output

Parameter Value
Max Configurable Power 4200 W
Harmonic Distortion < 5% at full load
Output Frequency (Sync) 57–63 Hz for 60 Hz nominal (sync to mains)
Output Frequency (Not Synced) 60 Hz ± 0.1%
Crest Factor Up to 5:1
Topology Double Conversion Online
Wave Type Sine Wave
Bypass Type Internal (Automatic and Manual)
Efficiency (Full Load) 85%
Max Configurable Power (VA) 6000 VA

Conformance

Parameter Value
Certifications CSA
Standards FCC Part 15 Class A, UL 1778

Environmental

Parameter Value
Operating Temperature Range 32–104 °F (0–40 °C)
Operating Relative Humidity 0–95%
Operating Altitude 0–10,000 ft
Storage Temperature Range 5–113 °F (-15–45 °C)
Storage Relative Humidity 0–95%
Storage Altitude 0–50,000 ft (0–15,240 m)
Acoustic Level 60 dBA
Online Thermal Dissipation 843 Btu/h

Based on 0 reviews

0.0 overall
0
0
0
0
0

Be the first to review “APC Symmetra RM 2kVA Scalable to 6kVA N+1 208/240V w/ 208 to 120V Step-Down Transformer (4) L5-20R”

There are no reviews yet.