S5736-S48S4X-A Specification
|
Item |
Specification |
Dimensions without packaging (H x W x D) [mm(in.)] |
Basic dimensions (excluding the parts protruding from the body): 43.6 mm x 442.0 mm x 220.0 mm (1.72 in. x 17.4 in. x 8.66 in.)
Maximum dimensions (the depth is the distance from ports on the front panel to the parts protruding from the rear panel): 43.6 mm x 442.0 mm x 228.0 mm (1.72 in. x 17.4 in. x 9.0 in.) |
Dimensions with packaging (H x W x D) [mm(in.)] |
90 mm Ć 555 mm Ć 345 mm (3.54 in. x 21.85 in. x 13.58 in.) |
Chassis height [U] |
1 U |
Typical power consumption [W] |
87 W |
Typical heat dissipation [BTU/hour] |
296.85 BTU/hour |
Maximum power consumption [W] |
111 W |
Maximum heat dissipation [BTU/hour] |
378.74 BTU/hour |
MTBF [year] |
41.97 year |
MTTR [hour] |
2 hour |
Availability |
>0.99999 |
Noise at normal temperature (acoustic power) [dB(A)] |
56.8 dB(A) |
Noise at normal temperature (acoustic pressure) [dB(A)] |
44.8 dB(A) |
Number of card slots |
0 |
Number of power slots |
0 |
Number of fans modules |
3 |
Redundant power supply |
Not supported |
Long-term operating temperature [°C(°F)] |
-5°C to +45°C (23°F to 113°F) at an altitude of 0-1800 m (0-5906 ft.) |
Short-term operating temperature [°C(°F)] |
-5°C to +50°C (23°F to 122°F) at an altitude of 0-1800 m (0-5906 ft.) |
Restriction on the operating temperature variation rate [°C(°F)] |
When the altitude is 1800-5000 m (5906-16404 ft.), the highest operating temperature reduces by 1°C (1.8°F) every time the altitude increases by 220 m (722 ft.).
The equipment can operate beyond the normal operating temperature range for a short-term period, but the following conditions must be met:
- The equipment operates at a temperature of over 45°C (113°F) consecutively for at most 96 hours in one year.
- The equipment operates at a temperature of over 45°C (113°F) for a total of no more than 360 hours in one year.
- The equipment operates at a temperature of over 45°C (113°F) for no more in 15 times in one year.
The equipment may be damaged or experience unexpected exceptions if any of the preceding limits is exceeded.
The equipment cannot start when the temperature is lower than 0°C (32°F). The maximum distance of optical modules used in these conditions cannot exceed 10 km. |
Storage temperature [°C(°F)] |
-40°C to +70°C (-40°F to +158°F) |
Long-term operating relative humidity [RH] |
5% to 95%, noncondensing |
Long-term operating altitude [m(ft.)] |
0-5000 m (0-16404 ft.) |
Storage altitude [m(ft.)] |
0-5000 m (0-16404 ft.) |
Power supply mode |
AC built-in |
Rated input voltage [V] |
- AC input: 100 V AC to 130 V AC, 200 V AC to 240 V AC, 50/60 Hz
- High-Voltage DC input: 240 V DC
|
Input voltage range [V] |
- AC input: 90 V AC to 290 V AC, 45 Hz to 65 Hz
- High-Voltage DC input: 190 V DC to 290 V DC
|
Maximum input current [A] |
6.0 A |
Memory |
2 GB |
Flash memory |
1 GB in total. To view the available flash memory size, run the display version command. |
Console port |
RJ45 |
Eth Management port |
RJ45 |
USB |
Not supported |
RTC |
Supported |
RPS input |
Not supported |
Service port surge protection [kV] |
– |
Power supply surge protection [kV] |
±6 kV in differential mode, ±6 kV in common mode |
Types of fans |
Built-in |
Heat dissipation mode |
Heat dissipation with fan, intelligent fan speed adjustment |
Airflow direction |
Air flows in from the left side and front panel, and exhausts from the right side. |
PoE |
Not supported |
Certification |
EMC certification
Safety certification
Manufacturing certification |