Galaxy VS UPS 80kW 400V for external batteries, halogen-free cables, marine certified, Start-up 5×8


AED242,499.00

Overview

Item Description
Presentation Highly efficient, easy-to-deploy 80kW, 400V 3-phase UPS for edge, small/medium data centers, commercial, and industrial applications. Includes 5×8 start-up service and halogen-free cables. Marine certified.
Lead Time Usually ships within 2 weeks

Main Electrical Specifications

Parameter Value
Main Input Voltage 400 V 3 phase
Other Input Voltage 380 V / 415 V
Main Output Voltage 400 V 3 phase
kW Rating 80 kW
Rated Power in VA 80 kVA
Battery Type External, Li-Ion, VRLA

Provided Equipment

Included
Dust filter
EcoStruxure IT ready (UPS)
Installation guide
Integrated network management
Power modules ship installed
Start-Up Service

Product Range

Range Compatibility
Galaxy VS Galaxy VS

Batteries & Runtime

Parameter Value
Battery Voltage 384–576 V DC
End of Discharge Voltage 307 V DC
Max Discharge Battery Current 217 A
Battery Power 0 VAh runtime
Extendable Runtime No

General Features

Parameter Value
Bypass Voltage Tolerance ±10%
Redundant No
Product Type Uninterruptible Power Supply (UPS)

Physical Specifications

Attribute Value
Color White
Height 58.46 in (148.5 cm)
Width 2.05 in (52.1 mm)
Depth 33.35 in (84.7 cm)
Weight 551.2 lb (250 kg)
USB Compatible No

Input Specifications

Parameter Value
Input Frequency 40 – 70 Hz
Efficiency at Full Load 340–460 V @ 400 V
Max Input Current per Phase 144 A
Max Short Circuit Withstand (Icw) 65 kA
Input THD < 3% at full load
Load Power Factor 0.7 leading to 0.7 lagging

Output Specifications

Parameter Value
Max Configurable Power (W / VA) 80 kW / 80 kVA
Output Frequency 50 Hz / 60 Hz (sync to mains)
Frequency Accuracy (Not Synced) ±0.1% for 50/60 Hz
Crest Factor 2.5
Waveform Type Sine wave
Output Voltage Tolerance ±1% after 50ms
Output Voltage THD < 1% linear load, < 5% non-linear load
Overload Operation 10 min @ 125%, 60 sec @ 150%
Bypass Type Built-in Static Bypass

Environmental Conditions

Condition Value
Operating Temp 32 – 104 °F (0 – 40 °C)
Operating Relative Humidity 0 – 95%, non-condensing
Operating Altitude 0 – 3300 ft
Storage Temp -13 – 131 °F (-25 – 55 °C)
Storage Relative Humidity 10 – 80%, non-condensing
Acoustic Level 68 dBA
Online Thermal Dissipation 8394 Btu/h
IP Degree of Protection IP21

Conformance & Standards

Standard / Certification
EN/IEC 62040-1
EN/IEC 62040-2
FCC Part 15 Class A
IEC 60721-4-2 Level 2M2
UL 1778 5th Edition

Based on 0 reviews

0.0 overall
0
0
0
0
0

Be the first to review “Galaxy VS UPS 80kW 400V for external batteries, halogen-free cables, marine certified, Start-up 5×8”